SYGS1 is a 12 kV SF6 gas-insulated ring main unit (RMU) with a fully sealed, fully insulated, maintenance-free structure for safe and reliable secondary distribution. Designed for 50 Hz three-phase 12 kV networks in industrial parks, commercial centers, and high-rise buildings. Complies with GB 3906, IEC 62271-200. The compact RMU supports looped and radial networks with load-break switch and fuse-combination options.
SYGS1 SF6 Gas-Insulated Ring Main Unit is an RFQ-configured high voltage switchgear for Industrial substations and Utility distribution rooms. Confirm five inputs before quotation: voltage class, rated current, single-line diagram, installation environment, and destination standard.
Model
SYGS1 / SF6 / G / I / R / M / U
Standard family
IEC 62271 / GB 3906 family, verify by product and project scope
Application scenarios
4 documented uses
RFQ minimum
5 engineering inputs
Verified Technical Specifications
Visible specifications and Product structured data use the same reviewed fact set.
Model Number
SYGS1 / SF6 / G / I / R / M / U
HS Code
RFQ required
Standard Compliance
IEC 62271 / GB 3906 family, verify by product and project scope
International Electrotechnical Commission · Accessed: 2026-07-28
Product Advantages
Structured from the supplied SJSY official product catalog dataset
Prepared for engineering RFQ instead of online checkout
Can be configured against buyer drawings, voltage class, site conditions, and project standards
Suitable for quotation review with SLD drawings and technical specifications
Application Scenarios
Industrial substations
Utility distribution rooms
Transport infrastructure
Mining and municipal projects
Applicable Solutions
These solution links are matched from the product category, model, and application scenarios so buyers can move from product review to project-level RFQ planning.
These references are sourced from the supplied engineering case file through the matched solution industries. Detailed outcomes, photos, and client proof remain reserved until verified.
Explore related equipment options when preparing the technical scope for your project quotation.
High Voltage Switchgear
DC Traction Power Supply Cabinet
DC traction power supply cabinet engineered for rail transit and mining traction networks. It steps down and rectifies AC to stable DC (commonly 750 V / 1500 V) for metro, light-rail, and trolley systems, with full protection, supervision, and remote signaling. Built for harsh traction environments with robust rectifier modules and complete protective functions. Compliant with IEC 62271 and relevant traction-power standards; suitable for subway, railway, and industrial DC traction applications.
KYN28A-12 is a 12 kV metal-clad, withdrawable AC switchgear using a center-mounted vacuum circuit breaker (VS1/ZN63A, VD4, HVX, EV12s). Rated for 50 Hz three-phase networks up to 12 kV, it handles power receiving, distribution, control, and protection in utilities, industry, transport, and municipal systems. Features an aluminum-zinc coated steel enclosure with separated compartments and complete five-prevention interlocks. Type-tested for internal arc (IAC) and conforms to GB 3906, GB/T 11022, DL/T 404, IEC 62271-1/200.
XGN2-12 Box-Type Fixed AC Metal-Enclosed Switchgear
XGN2-12 is a 12 kV box-type fixed AC metal-enclosed switchgear for 50 Hz three-phase networks. Its compact fixed structure minimizes footprint and simplifies maintenance, with ZN28/ZN63 vacuum circuit breakers. Used for power reception and distribution with control, protection, and monitoring across utilities, industry, building, transport, and municipal sectors. Conforms to GB 3906, GB/T 11022, DL/T 404, IEC 62271-1/200. A cost-effective choice for standard distribution substations.
XGN15-12 Box-Type Fixed AC Metal-Enclosed Switchgear
XGN15-12 is a 12 kV SF6 gas-insulated, box-type fixed AC metal-enclosed switchgear. The SF6-insulated design is compact, maintenance-free, and highly reliable for secondary distribution. Suitable for 12 kV three-phase 50 Hz networks in utilities, industry, transport, and municipal applications. Conforms to GB 3906, GB/T 11022, IEC 62271-200. Ideal where space is constrained and long service life with minimal upkeep is required.
KYN28-24 is a 24 kV metal-clad, withdrawable AC switchgear with a center-mounted vacuum circuit breaker and complete five-prevention interlocks. Designed for 50 Hz three-phase 24 kV networks, it performs power receiving, distribution, control, and protection in utilities, industry, building materials, and transport. Complies with GB 3906, GB/T 11022, DL/T 404, IEC 62271-200. The withdrawable truck design enables safe, fast breaker isolation and maintenance.
SYSS1-12 is a 12 kV indoor AC metal-enclosed switchgear with a modular, compact design and reliable performance for 50 Hz three-phase 12 kV networks. Used for power reception and distribution with control, protection, and monitoring in utilities, industry, building materials, transport, and municipal systems. Conforms to GB 3906, IEC 62271-200. Suitable for indoor substations and industrial power rooms requiring space-efficient, serviceable switchgear.
Can SYGS1 SF6 Gas-Insulated Ring Main Unit be quoted for an overseas project?
Yes. Submit the project SLD, voltage class, rated current, installation environment, destination country, and preferred component ecosystem so the engineering team can review the quotation scope.
Why does this source catalog page not show a public price?
Industrial electrical equipment is configured by project drawings, electrical parameters, component brands, testing requirements, packing, and delivery terms. The site uses RFQ instead of checkout or public pricing.
Are source images and source IDs preserved?
The source product ID, category, source URL, and image URL are preserved for traceability. Public claims remain limited to supplied source material and RFQ-ready product descriptions.
What information is required for an engineering quotation?
Provide five core inputs: voltage class, rated current, single-line diagram, installation environment, and destination standard. Component preferences, quantities, delivery terms, and testing requirements improve quotation accuracy.
How should buyers verify standards compliance before ordering?
Use IEC 62271 / GB 3906 family, verify by product and project scope as the initial standard family, then confirm the exact model scope, destination requirements, technical agreement, type-test evidence, and FAT plan with the engineering team before production.